º¸¾È Á¢¼Ó
Back-UPS (º¸±ÞÇü)
Smart-UPS (°í±ÞÇü)
Smart-UPS LCD (°í±ÞÇü)
Smart Connect
Smart-UPS SRT/RT (¿Â¶óÀÎ)
SRV EASY UPS ¿Â¶óÀÎ
APC UPS ±³Ã¼¹èÅ͸®
Smart-UPS RT(SRT) Ãß°¡ ¹èÅ͸®ÆÑ
ÀÔ/Ãâ·Â Àü¿øÄÉÀ̺í
¼Áöº¸È£ ¸ÖƼÅÇ
Network Card
Rack PDU
Symmetra-LX(¸ðµâÇü)
Smart-UPS VT (3»ó)
Symmetra PX(3»ó¸ðµâ)
MGE Galaxy 3500
MGE Galaxy 5000
MGE Galaxy 6000
MGE Galaxy 7000
MGE Galaxy 9000
ATS (Àü¿øÀÌÁßÈÀåÄ¡)
Rack System (19ÀÎÄ¡)
APC Marine (¼±¹Ú)
APC 120V
°³ÀΰáÁ¦Ã¢
°øÁö»çÇ×
Áú¹®°ú ´ë´ä
ÀÚ·á½Ç
E-mail·Î
¹®ÀÇÇϱâŬ¸¯
±â¾÷ 261-055-214-01-0
±¹¹Î 205701-04-234012
ºñ¹Ð¹øÈ£
Smart-UPS SRT/RT (¿Â¶óÀÎ)
Smart-UPS SRT/RT (¿Â¶óÀÎ)
>
SURT2000XLI / 2KVA(1400W) ·¢Å¸¿ö°â¿ëÁ¦Ç°
SURT2000XLI / 2KVA(1400W) ·¢Å¸¿ö°â¿ëÁ¦Ç°
Á¦Á¶È¸»ç : APC
ÆÇ¸Å°¡°Ý :
1,449,500¿ø
¹è¼ÛÁ¶°Ç : (Á¶°Ç)
¹è¼ÛÁ¶°Ç : (Á¶°Ç)
ÃÑ °áÁ¦±Ý¾×ÀÌ
80,000¿ø
¹Ì¸¸½Ã
¹è¼Ûºñ
4,000¿ø
ÀÌ Ã»±¸µË´Ï´Ù.
¼ö·®
EA
Ãâ·Â
Ãâ·Â ¿ë·®
1400 Watts / 2000 VA
ÃÖ´ë ±¸¼º Àü·Â
1400 Watts / 2000 VA
°øÄª Ãâ·Â Àü¾Ð
230V
Output Voltage Note
220 : 230 ¶Ç´Â 240 °øÄª Ãâ·Â Àü¾Ð¿¡ ´ëÇØ ±¸¼º°¡´É
100% ºÎÇÏ¿¡¼ÀÇ È¿À²
90%
Ãâ·ÂÀü¾Ð ÆÄÇü ¿ÖÀ²
3% ÀÌÇÏ
Ãâ·ÂÁ֯ļö(Àü¿ø¿¡ µ¿±â)
50/60Hz +/- 3Hz ~ +/- 0.1 »ç¿ëÀÚ Á¶Á¤ °¡´É
Crest Factor
3 : 1
ÆÄÇü
Á¤ÇöÆÄ
Ãâ·Â¹è¼±¿¬°á
(6) IEC 320 C13
(2) IEC Jumpers
Bypass
³»Àå ¹ÙÀÌÆÐ½º
ÀÔ·Â
°øÄª ÀÔ·Â Àü¾Ð
230V
ÀÔ·Â Á֯ļö
50/60 Hz +/- 5Hz (ÀÚµ¿ °¨Áö)
ÀԷ¹輱¿¬°á
IEC-320 C20
Schuko CEE 7 / EU1-16P
British BS1363A
ÄÚµå ±æÀÌ
2.44 ¹ÌÅÍ
Çã¿ë ÀÔ·Â Àü¾Ð ¹üÀ§
160 - 280V
Çã¿ë ÀÔ·Â Àü¾Ð Á¶Á¤ ¹üÀ§
100 - 280V
±âŸ ÀÔ·Â Àü¾Ð
220,240
¹èÅ͸® & Á¤Àüº¸»ó½Ã°£
¹èÅ͸® À¯Çü
¹«º¸¼ö ¹«´©¾× ¿¬ÃàÀüÁö(sealed Lead-Acid battery) : ´©¾×¹æÁö
»çÀü ¼³Ä¡µÈ ¹èÅ͸®
1
ÀϹÝÀûÀÎ ÃæÀü½Ã°£
4 ½Ã°£
±³Ã¼ ¹èÅ͸® īƮ¸®Áö
RBC31
RBC¢â ¼ö·®
1
Extended run options for
APC Smart-UPS RT 2000VA 230V
<========Á¤Àüº¸»ó½Ã°£ º¸±â
Åë½Å & °ü¸®
ÀÎÅÍÆäÀ̽º Æ÷Æ®
DB-9 RS-232,SmartSlot
SmartSlot¢â ÀÎÅÍÆäÀ̽º ¼ö·®
1
Á¦¾îÆÇ
ºÎÇÏ¿Í ¹èÅ͸® ¸·´ë±×·¡ÇÁ ¹× On Line : On Battery : Replace Battery : and Overload Indicator°¡ ÀÖ´Â LED »óÅ µð½ºÇ÷¹ÀÌ
°æº¸À½
¹èÅ͸® »ç¿ëÁßÀÏ ¶§ °æº¸ : Àú¹èÅ͸® °æº¸ : °úºÎÇÏ ¿¬¼Ó Åæ °æº¸
Emergency Power Off (EPO)
¿É¼Ç
¼Áö ¹æÁö ¹× ÇÊÅ͸µ
¼Áö ¿¡³ÊÁö Á¤°Ý
420 ÁÙ(Joule)
ÇÊÅ͸µ
Àü½Ã°£ ´ÙÁß±Ø ÀâÀ½ ÇÊÅ͸µ : 0.3% IEEE ¼Áö ·¿½º·ç : Á¦·Î Ŭ·¥ÇÎ ÀÀ´ä½Ã°£ : UL 1449 ÃæÁ·ÇÕ´Ï´Ù
¿ÜÇü
ÃÖ´ë ³ôÀÌ
432.00 mm
ÃÖ´ë Æø
85.00 mm
ÃÖ´ë ±íÀÌ
483.00 mm
·¢ ³ôÀÌ
2U
¼øÁß·®
25.00 KG
¼±Àû Áß·®
29.82 KG
¼±Àû ³ôÀÌ
286.00 mm
¼±Àû Æø
630.00 mm
¼±Àû ±íÀÌ
594.00 mm
»ö»ó
Black
Units per Pallet
12.00
ȯ°æ
ÁÖÀ§ ¿Âµµ(µ¿ÀÛ½Ã)
0 - 40 ¡ÆC
»ó´ë ½Àµµ(µ¿ÀÛ½Ã)
0 - 95%
°íµµ(µ¿ÀÛ½Ã)
0-3000 ¹ÌÅÍ
º¸°ü ¿Âµµ
-20 - 50 ¡ÆC
º¸°ü »ó´ë ½Àµµ
0 - 95%
º¸°ü °íµµ
0-15000 ¹ÌÅÍ
¼ÒÀ½(1m °Å¸®)
50.00 dBA
¹ß¿·®
543.00 BTU/hr
ÀûÇÕ ±Ô°Ý
½ÂÀÎ
C-tick,CE,EN 50091-1,EN 50091-2,EN 55022 Class A,EN 60950,EN 61000-3-2,GOST,VDE
Ç¥ÁØ º¸Áõ
2³â,ÇöÀå º¸Áõ ¿É¼Ç ÀÌ¿ë °¡´É,º¸Áõ ¿¬Àå ¿É¼Ç ÀÌ¿ë °¡´É
À̸§ :
³»¿ë :
ÆòÁ¡
¡Ú
¡Ú¡Ú
¡Ú¡Ú¡Ú
¡Ú¡Ú¡Ú¡Ú
¡Ú¡Ú¡Ú¡Ú¡Ú
°í°´Æò°¡ :
ÆòÁ¡
¡Ú¡Ú¡Ú¡Ú¡Ú
¹øÈ£
Á¦¸ñ
ÀÛ¼ºÀÚ
Á¶È¸
[»èÁ¦]
[Ãë¼Ò]
[
ÀÌ¿ë¾à°ü
] [
°³ÀÎÁ¤º¸ º¸È£Á¤Ã¥
] [
ÀÌ¿ë¾È³»
]
´ëÇ¥ : ¹®Çå¼± l »óÈ£¸í : ¿ì¸®À¯ÇÇ¿¡½º l »ç¾÷ÀÚµî·Ï¹øÈ£ : 206-27-53946
[»ç¾÷ÀÚÁ¤º¸È®ÀÎ]
Åë½ÅÆÇ¸Å¾÷½Å°í¹øÈ£ : Á¦2019-°æ±â±¸¸®-0008È£ ÀüÈ: 02-3296-1588,070-7098-1588
»ç¾÷Àå¼ÒÀçÁö : °æ±âµµ ±¸¸®½Ã °¥¸Å¼øÈ¯·Î204¹ø±æ 65 , ½º¸¶Æ®º¥Ã³Å¸¿ö 708È£
l °³ÀÎÁ¤º¸´ã´çÀÚ :
¹®Çå¼±
Copyright ¨Ï
APCÃÑÆÇAPCÀü¹® APCMARKETÀÔ´Ï´Ù.
Copyright © APCmarket All Rights Reserved.-¹«´Ü»ç¿ë±ÝÁö ¸ÞÀÏ:apc@apcmarket.com À̸ÞÀÏ ÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ