º¸¾È Á¢¼Ó
·Î±×ÀÎ ºñ¹Ð¹øÈ£ ȸ¿ø°¡ÀÔ
ȨÀ¸·Î ȸ»ç¼Ò°³ ÀÌ¿ë¾È³» ÁÖ¹®Á¶È¸ ¸¶ÀÌÆäÀÌÁö Àå¹Ù±¸´Ï °Ô½ÃÆÇ
1. Back-UPS (º¸±ÞÇü)
2. APC BV / BVX UPS
3. APC BX UPS
4. Smart-UPS (°í±ÞÇü)
5. Smart-UPS LCD (°í±ÞÇü)
6. SMT-SMC-Smart Connect (½º¸¶Æ®Ä¿³ØÆ®)
7. SMV EASY UPS
8. Smart-UPS SRT/RT (¿Â¶óÀÎ)
9. SRV EASY UPS ¿Â¶óÀÎ
10. SRTG UPS ¿Â¶óÀÎ
11. APC UPS ±³Ã¼¹èÅ͸®
12. SRT/RT Ãß°¡ ¹èÅ͸®ÆÑ
13. ÀÔ/Ãâ·Â Àü¿øÄÉÀ̺í
14. ¼­Áöº¸È£ ¸ÖƼÅÇ
15. Rack PDU
16. ATS (Àü¿øÀÌÁßÈ­ÀåÄ¡)
17. EASY PDU
18. Rack System (19ÀÎÄ¡)
19. APC Marine (¼±¹Ú)
20. ¸®Æ¬ÀÌ¿Â ¹èÅ͸® UPS
21. Network Card
22. EASY UPS 3S 3»ó 15-40KVA
23. EASY UPS 3M 3»ó 60-200KVA
24. APC 120V
25. Symmetra PX(3»ó¸ðµâ)
26. °³ÀΰáÁ¦Ã¢
°Ë»ö
°øÁö»çÇ×
Áú¹®°ú ´ë´ä
ÀÚ·á½Ç

E-mail·Î
¹®ÀÇÇϱâŬ¸¯
 
 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
15. Rack PDU 15. Rack PDU > Switched RACK PDU Àü·Â ¸ð´ÏÅ͸µ ¿ø°Ý ON/OFF > AP7922B (32A) ·¢ PDU, ½ºÀ§Ä¡ ÀåÂø, 2U, 32A, 230V, (16)C13  
   AP7922B (32A) ·¢ PDU, ½ºÀ§Ä¡ ÀåÂø, 2U, 32A, 230V, (16)C13
  
Á¦Á¶È¸»ç : APC
ÆǸŰ¡°Ý : °ßÀû¹®ÀÇ
APC Switched Rack PDU, ÀÔ·Â: 200V, 208V, 230V, ÀÔ·Â ¿¬°á: IEC 309 32A 2P+E, ÄÚµå ±æÀÌ:10 feet ( 3.05 ¹ÌÅÍ ), Ãâ·Â: 230V, Ãâ·Â ¿¬°á: IEC 320 C13
¹è¼ÛÁ¶°Ç : (Á¶°Ç)
¼ö·® EA
 
 
    
 
 
 
 
 
 


·¢ PDU, ½ºÀ§Ä¡ ÀåÂø, 2U, 32A, 230V, (16)C13


AP7922B Æ¯Â¡

ÇÙ½É Æ¯Â¡

·¢ ³ôÀÌ
2U
Ãâ·Â ¿¬°á
(16) IEC 60320 C13
°øĪ Ãâ·Â Àü¾Ð
230V
°øĪ ÀÔ·Â Àü¾Ð
200V, 208V, 230V
ÀÔ·Â ¿¬°á
IEC 60309 32 A 2P + E
·¢ PDU, ½ºÀ§Ä¡ ÀåÂø, 2U, 32A, 230V, (16)C13
½ºÀ§Ä¡ ·¢ PDU´Â Àü·Â »çÀÌŬ¸µ, Áö¿¬µÈ Àü·Â ½ÃÄö½Ì, Äܼ¾Æ® »ç¿ë °ü¸®¸¦ À§ÇÑ °³º° Äܼ¾Æ® ½ºÀ§Äª Á¦¾î¿ë ¿ø°Ý ¿Â/¿ÀÇÁ ±â´É°ú °áÇÕµÈ ¹ßÀüÇü ºÎÇÏ ¸ð´ÏÅ͸µ ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù.
Æ÷ÇÔ»çÇ×: ¼³¸í¼­ CD, ¼³Ä¡ °¡À̵å, Rack mounting brackets

Ç÷¡½Ã ¾÷±×·¹ÀÌµå °¡´É

ÃßÈÄ Á¦Ç° Çâ»ó ½Ã ³×Æ®¿öÅ© ´Ù¿î·Îµå¸¦ ÅëÇØ Æß¿þ¾î¸¦ ½±°í ºü¸£°Ô ¾÷±×·¹À̵åÇÒ ¼ö ÀÖ½À´Ï´Ù. »õ ±â´ÉÀÌ ¹ßÇ¥µÇ¾úÀ» ¶§ ÇöÀå¿¡ ÀÌ¹Ì ¼³Ä¡µÇ¾î ÀÖ´Â Á¦Ç°À» ±³Ã¼ÇÒ ÇÊ¿ä°¡ ¾ø½À´Ï´Ù. (Âü°í: ³×Æ®¿öÅ© ¿¬°áµÈ ÀåÄ¡¿¡¸¸ ÇØ´ç)

NetShelter ½ºÀ§Ä¡ ·¢ PDU Æ¯Â¡ ¹× ÀåÁ¡

½Å¼Ó¼º

Ç÷¡½Ã ¾÷±×·¹ÀÌµå °¡´É
ÃßÈÄ Á¦Ç° Çâ»ó ½Ã ³×Æ®¿öÅ© ´Ù¿î·Îµå¸¦ ÅëÇØ Æß¿þ¾î¸¦ ½±°í ºü¸£°Ô ¾÷±×·¹À̵åÇÒ ¼ö ÀÖ½À´Ï´Ù. »õ ±â´ÉÀÌ ¹ßÇ¥µÇ¾úÀ» ¶§ ÇöÀå¿¡ ÀÌ¹Ì ¼³Ä¡µÇ¾î ÀÖ´Â Á¦Ç°À» ±³Ã¼ÇÒ ÇÊ¿ä°¡ ¾ø½À´Ï´Ù. (Âü°í: ³×Æ®¿öÅ© ¿¬°áµÈ ÀåÄ¡¿¡¸¸ ÇØ´ç)
Wireless Connectivity
Compatible with the optional APC USB WiFi Device for cableless connectivity over WiFi that speeds deployment and simplifies moves, adds, and changes (9000 Series PDUs only - expected to be available on units manufactured after March 2021).

ÀûÀÀ¼º

´Ù¾çÇÑ ÀÔ·Â ¹× Ãâ·Â ¿¬°á
ÀÌ Á¦Ç°±º¿¡´Â 120V, 208V ¶Ç´Â 230V Àü¿øÀ» ¿©·¯ Äܼ¾Æ®·Î ºÐ¹èÇÒ ¼ö ÀÖ´Â ´Ù¾çÇÑ ÀÔ·Â ¹× Ãâ·Â ¿¬°áÀÌ Æ÷ÇԵǾî ÀÖ½À´Ï´Ù. ´Ù¾çÇÑ ÀÔ/Ãâ·ÂÀ» Á¦°øÇϹǷΠ»ç¿ëÀÚ°¡ ´Ù¾çÇÑ Àü¿ø ¿ä±¸ »çÇ׿¡ ¸Â°Ô º¯°æÇÒ ¼ö ÀÖ½À´Ï´Ù. APC´Â ´ÜÁö¼± À¬(single branch whip)À» »ç¿ëÇÏ¿© ÃÖ´ë 5.7kW±îÁö °ø±ÞÇÒ ¼ö ÀÖ´Â ÀåÄ¡¸¦ Á¦°øÇÕ´Ï´Ù.
´ÜÀÏ ÀÔ·Â Àü¿ø
´ÜÁö¼± À¬¿¡¼­ ¿©·¯ Àåºñ ºÎºÐÀ¸·Î Àü¿øÀ» °ø±ÞÇϹǷΠ·¢ žÀç Àåºñ¿¡ Æí¸®ÇÏ°Ô Àü¿øÀ» °ø±ÞÇÒ ¼ö ÀÖ½À´Ï´Ù. ´ÜÁö¼± À¬°ú Ç¥ÁØ ¿¬°áÀ» »ç¿ëÇÏ¿© ¼³Ä¡ ½Ã ½Ã°£ ¹× ºñ¿ëÀ» Àý°¨ÇÒ ¼ö ÀÖ½À´Ï´Ù.
·¢ žÀç °¡´É
·¢ °ø°£ 1U¸¸À» Â÷ÁöÇϹǷΠÀåÄ¡¸¦ 19" ·¢ ¶Ç´Â ÀÎŬ·ÎÀú¿¡ ½±°í Æí¸®ÇÏ°Ô Å¾ÀçÇÒ ¼ö ÀÖ½À´Ï´Ù. ÇÊ¿äÇÑ Àü¿øÀ» ·¢¿¡ ¸ðµÎ °ø±ÞÇÒ ¼ö ÀÖ½À´Ï´Ù.

°¡¿ë¼º

C13/C15 and C19/C21 Hybrid Outlets
Available on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords.
High Retention Outlets
With no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs.
Field-replaceable NMC
Integrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure.
60C Operating Temperature
Select 9000 series PDUs provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F).
Hydraulic Magnetic Circuit Breakers
Provide increased availability by maintaining trip current over a wide temperature range.

°ü¸®¿ëÀ̼º

1% Metering Accuracy
Providing the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use these PDUs to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Available on 9000 series PDUs.
³×Æ®¿öÅ© Æ÷Æ® °øÀ¯
ÀÔÃâ·Â Æ÷Æ®¸¦ »ç¿ëÇÏ¿© ³× °³ÀÇ ·¢ PDU¸¦ ¿¬°áÇÒ ¼ö ÀÖÀ¸¹Ç·Î ÇϳªÀÇ ³×Æ®¿öÅ© ¿¬°á¸¸ ÇÊ¿äÇÕ´Ï´Ù.
°æº¸ ÀÓ°è°ª
ȸ·Î °úºÎÇϸ¦ ÇÇÇÒ ¼ö ÀÖµµ·Ï °æº¸ ÀÓ°è°ªÀ» Á¤ÀÇÇÒ ¼ö ÀÖ½À´Ï´Ù. ³×Æ®¿öÅ© ¹× °¡½Ã °æº¸´Â ¿¹»ó ¹®Á¦¸¦ »ç¿ëÀÚ¿¡°Ô ¾Ë·ÁÁÝ´Ï´Ù. (Âü°í: Àü·ù ¸ð´ÏÅ͸µ ±â´ÉÀÌ ÀÖ´Â ÀåÄ¡¿¡¼­¸¸ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. °¡¿ë ¿©ºÎ´Â SKU »ç¾çÀ» ÂüÁ¶ÇϽʽÿÀ.)
Outlet Level Grouping
Outlet power sequencing can be configured to group any combination of outlets to power up or down together providing flexibility.
°æº¸ ÀÓ°è°ª
ȸ·Î °úºÎÇϸ¦ ÇÇÇÒ ¼ö ÀÖµµ·Ï °æº¸ ÀÓ°è°ªÀ» Á¤ÀÇÇÒ ¼ö ÀÖ½À´Ï´Ù. ³×Æ®¿öÅ© ¹× °¡½Ã °æº¸´Â ¿¹»ó ¹®Á¦¸¦ »ç¿ëÀÚ¿¡°Ô ¾Ë·ÁÁÝ´Ï´Ù.
Enhanced Cybersecurity
9000 series PDUs include APC Network Management card with security features including secured interfaces and a modified password policy providing peace of mind.
EcoStruxure IT Ready
Seamless integration of one or many PDUs including alerts and control with EcoStruxure IT. Allows IT and data center professionals to monitor and manage all of their critical IT infrastructure on-premise, in the cloud, and at the edge from anywhere.
Gigabit Ethernet Connectivity
9000 series PDUs provide Gigabit Ethernet to enhance and standardize network connectivity across all assets in the data center. All other models provide 10/100 ethernet connectivity.
´Ù´Ü°è »ç¿ëÀÚ ¾×¼¼½º
»ç¿ëÀÚ À̸§°ú ¾ÏÈ£·Î °ü¸®ÀÚ, ÀåÄ¡ »ç¿ëÀÚ, Àбâ Àü¿ë »ç¿ëÀÚ, ³×Æ®¿öÅ© Àü¿ë »ç¿ëÀÚ µî ÃÖ´ë 4°³ÀÇ ¾×¼¼½º ¼öÁØÀ» Áö¿øÇÕ´Ï´Ù.
³×Æ®¿öÅ© °ü¸® ±â´É

Web, SNMP ¹× TelnetÀ» ÅëÇÏ¿© Ç¥ÁØ ±â¹ÝÀÇ °ü¸®¸¦ Á¦°øÇÏ´Â ¶Ù¾î³­ ±â´ÉÀÇ ³×Æ®¿öÅ© °ü¸® ÀÎÅÍÆäÀ̽º. »ç¿ëÀÚ´Â ¿ø°Å¸®¿¡¼­ ÀåÄ¡¿¡ Á¢±Ù, ±¸¼º, °ü¸®ÇÒ ¼ö ÀÖ¾î ½Ã°£À» Àý¾àÇÒ ¼ö ÀÖ½À´Ï´Ù. ÀÌ ±â´É°ú °ü·ÃµÈ °ÍÀ¸·Î ÇâÈÄ Á¦Ç°ÀÇ Çâ»óÀ» À§ÇØ ¼³Ä¡µÈ ÀåÄ¡ÀÎ ³×Æ®¿öÅ© ´Ù¿î·Îµå¸¦ ÀÌ¿ëÇϸé Æß¿þ¾î¸¦ ½Å¼ÓÇÏ°í ¿ëÀÌÇÏ°Ô ¾÷±×·¹À̵åÇÒ ¼ö ÀÖ½À´Ï´Ù.


Ãâ·Â

ÃÖ´ë ÃÑ Àü·ù ¿ä±¸·®
32

ÀÔ·Â

ÀÔ·Â ÁÖÆļö
90 - 264 V
Çã¿ë °¡´ÉÇÑ ÀÔ·Â Àü¾Ð
220 - 240VAC
Àü·Â ÄÚµå ¼ö
1
ºÎÇÏ ¿ë·®
7360VA
ÃÖ´ë ÀÔ·Â Àü·ù
32A

¹°¸®Àû ±Ô°Ý

ÃÖ´ë ³ôÀÌ
89mm, 8.9cm
ÃÖ´ë Æø
445mm, 44.5cm
ÃÖ´ë ±íÀÌ
114mm, 11.4cm
¼øÁß·®
4.5kg
¼±Àû Áß·®
6.55kg
¼±Àû ³ôÀÌ
140mm, 14.0cm
¼±Àû Æø
508mm, 50.8cm
¼±Àû ±íÀÌ
368mm, 36.8cm
»ö»ó
°ËÀº»ö

ȯ°æ ¿ä±¸ »çÇ×

ÀÛµ¿ ¿Âµµ
0 - 45 ¡ÆC
ÀÛµ¿ »ó´ë ½Àµµ
0 - 95 %
ÀÛµ¿ °íµµ
0 - 3048¹ÌÅÍ
º¸°ü ¿Âµµ
-25 - 65 ¡ÆC
º¸°ü »ó´ë ½Àµµ
0 - 95 %
º¸°ü °íµµ
0 - 15240¹ÌÅÍ

Áؼö »çÇ×

±ÔÁ¤ ½ÂÀÎ
CE, EN 55022 Ŭ·¡½º A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, VDE
Ç¥ÁØ º¸Áõ
2³â

Áö¼Ó °¡´ÉÇÑ ¿ÀÆÛ »óÅÂ

RoHS

Áؼö




 
 
 
À̸§ :
³»¿ë :
ÆòÁ¡
°í°´Æò°¡ : ÆòÁ¡ ¡Ú¡Ú¡Ú¡Ú¡Ú     
 
 
 
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ Á¶È¸
 
 

[ÀÌ¿ë¾à°ü] [°³ÀÎÁ¤º¸ º¸È£Á¤Ã¥] [ÀÌ¿ë¾È³»]

´ëÇ¥ : ¹®Çå¼± l »óÈ£¸í : (ÁÖ)¿ì¸®À¯ÇÇ¿¡½º l »ç¾÷ÀÚµî·Ï¹øÈ£ : 653-81-02887 653-81-02887
Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦2022-°æ±â±¸¸®-0964È£ ÀüÈ­: 02-3296-1588,070-7098-1588
»ç¾÷Àå¼ÒÀçÁö : °æ±âµµ ±¸¸®½Ã °¥¸Å¼øȯ·Î204¹ø±æ 65 , ½º¸¶Æ®º¥Ã³Å¸¿ö 608È£ l °³ÀÎÁ¤º¸´ã´çÀÚ : ¹®Çå¼±
Copyright ¨Ï APCÃÑÆÇAPCÀü¹® APCMARKETÀÔ´Ï´Ù. Copyright © APCmarket All Rights Reserved.-¹«´Ü»ç¿ë±ÝÁö ¸ÞÀÏ:apc@apcmarket.com À̸ÞÀÏ ÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ